USER GUIDE
9
Figure 11 ASCII setup
16. Open any text editor to type commands into.
IMPORTANT!
Type the commands as set out in the table below into the text editor. Copy and
paste them into the Hyperterminal by right-clicking inside the Hyperterminal, a
menu appears, click Paste to Host.
Description Command Comment
Echo Device Address ^isP003EAD ^iSWITCH01,^iSWITCH02,
Echo Homepage ^isPxxx(len)HMEfilename ^iDXXXXX, XXXXX is len
Address Start ^isS005ADRxx ^isS005ADRxx, Address xx start
Address End ^isS003END
Outlet on ^isS004ONSn ^isS004ONS1-8, outlet 1-8on
Outlet off ^isS004OFSn ^isS004OFS1-8 outlet 1-8off
Echo Status ^isP003STS ^iDXXXnn(Address),nn, outlet status
(S1,S2,S3,S4,S5,S6,S7,S8), nn is outlet
number, S1-8, 0 off, 1 on, 2 pending, 3 fault
Configure Address ^isS005CFGxx ^isS005CFGxx, configure current address to
address xx
Set outlet Identification ^isSxxx(len)UIDn,Identification ^isSxxx(len)UIDn, Identification, set outlet(0-
8) Identification, 0 is SRP Manager
identification
Get outlet Identification ^isP003UID ^iDxxx(len)0iden,1iden,2iden,3iden,4iden,
5iden, 6iden,7iden,8iden
xx(1-7 Date), n(outlet 1-
8) , D(1,0) 1 is enable, 0
is disable, X(1,0) 1 is on
timer, 0 is off timer, HH is
hour, MM is minutes
^isSxxx(len)SCHxx,n,D,X,HHM
M,xx,n,D,X,HHMM
^isS016SCH01,1,1,1,1200
xx(1-7 Date), n(1-8 sw) ^isP007SCHxx,n ^iDxxx(len)D,1,HHMM,D, 0,HHMM, D 1 is
enable, 0 is disable, 1HHMM is time on,
0HHMM is time off