Upgrading the Supervisor Phantom firmware
8-11
10. In the
Phantom Update
program, check that the
firmware version number appears.
Contact our Technical Support department, if the OSD
will not display, or the firmware version number fails to
appear.
The Slave unit
When updating a
Slave
unit and a Communication Error
message appears, do the following:
1. Check that the Communication cable’s Stereo plug is
connected to the
Manager’s
Communication port.
2. Check that the Communication cable’s DB9F
connector is connected to the DB9M Serial port on
the CPU’s rear panel.
3. Check that the System cable, is connected.
4. Restart the download process from page 8-3, AND
make sure the Firmware Upgrade mode is activated.
Electricity failure or a rattling noise
When the electricity fails while updating the
Slave
firmware, or if you hear a rattling noise from the relay on
the
Slave
cards, do the following:
1. Switch off and disconnect the
Slave
computer from
the power supply.
2. Open the cover of the
Slave
computer extract the
Slave
card and close Jumper
JP9
. See Figure 8-8.
Vue de la page 69